Snap in electrolytic capacitor reliability index Cadaa ad militum & defensio
- Sunt fidem Indicatores, et sunt quinque gradus defectus rate(λ≤1×10-5)
- Occurrit environmental requisitis vibrationis, humilis pressura, humiditas resistentia et alia requisita environmental vexillum militaris nationalis GJB603-88
- Convenit ad eliquare, copulare et bypassing in electronic circuitus in aerospace, aviation, alpine, alta altitudo et Oceanum
| Item | proprium | ||||||||||||||
| Operans temperatus range | -55~+105℃ | ||||||||||||||
| Rated voltage range | 10V~500V | ||||||||||||||
| Nominal facultatem range | 47μF~68000μF | ||||||||||||||
| Allowable deviation of nominal capacitance(25℃,100Hz) | M(±20% | ||||||||||||||
| DC lacus current(25℃,5min) | I≤0.02CRUR(μA)
CR:Capacitas nominalμF);UR:Rated voltage(V) |
||||||||||||||
|
Dissipation factor tgδ(25℃,100Hz) |
UR(V) | 10 | 16 | 25 | 35 | 50 | 63 | 80 | 100 | 160~450 | 500 | ||||
| tgδ(≤) | 0.20 | 0.18 | 0.15 | 0.12 | 0.10 | 0.10 | 0.10 | 0.10 | 0.15 | 0.20 | |||||
| Products with capacities greater than 1500μF,Each increase1000μF,The dissipation
factor increases0.02。 |
|||||||||||||||
| Temperatus characteres
(100HZ) |
Ratio impedimentum | Z-55℃/Z+25℃≤15 | |||||||||||||
| Rate of change
in capacitance |
(C+25℃-C-55℃)/C+25℃≤20%(≤40%(500V))
(C+25℃-C-40℃)/C+25℃≤10%(≤20%(500V)) |
||||||||||||||
|
firmitatem |
The rated voltage with ripple current is applied at 105°C for 2000h, et post
recuperatio pro 24h *, in rated voltage cum tremor current probata ad locus temperatus (25°C±5°C), and its electrical performance is in accordance with the test : |
||||||||||||||
| Rate mutationis in capacitate | ≤ ± XV% Coepi mensurae | ||||||||||||||
| The dissipation factor tgδ | ≤150% Initial prescriptive value | ||||||||||||||
| DC lacus current | ≤Initial praescriptio pretii | ||||||||||||||
|
Condite in altum temperaturis |
After being left at 105 °C for 500h and recovered for 24 horulus, the electrical performance was tested at room temperature (25 °C±5 °C). : | ||||||||||||||
| Rate mutationis in capacitate | ≤ ± XV% Coepi mensurae | ||||||||||||||
| Angulus amissus tangens tgδ | ≤200% Coepi praescriptum valorem | ||||||||||||||
| DC lacus current | ≤200% Coepi praescriptum valorem | ||||||||||||||