Radiálny polymér Elektrolytický kondenzátor ultra nízky ESR CaBAB pre armádu & obhajoba
- Conductive polymer solid-state electrolyte is used to achieve ultranízke ESR.
- Vynikajúca absorpcia rušenia. Excellent temperature and frequency
- The national military standard level meets the environmental requirements of vibration and low
- It is suitable for energy storage, filtrovanie a bypass v elektronických obvodoch v letectve, letectva, studený, high altitude and ocean
Empty tab. Ak chcete pridať obsah sem, upravte stránku.
Funkcie
◆ 105 ° C, 1000 Zaistené hodiny.
◆ Štandardná miniatúrna veľkosť s výškou 5 mm.
◆ Dodržiavanie predpisov ROHS

| item | characteristic | ||||
| Operating temperature range | -55℃~+105℃ | ||||
| Rated operating voltage range | 40V~80V | ||||
| Nominal capacitance range | 68μF~2200μF | ||||
| Allowable deviation
nominálna kapacita |
of | M(±20%) | (25℃,120Hz) | ||
| DC leakage current*1 | I≤0.01CRUR (25℃,2min)
CR: Nominal capacitance (μf); Ur: Menovité napätie (Vložka) |
||||
| Loss tangent tgδ (max) | For details, please refer to the “List of Product Specifications and Technical Parameters”
(25℃,120Hz) |
||||
| ESR(max)*2 | For details, please refer to the “List of Product Specifications and Technical Parameters”
(25℃,100KHz) |
||||
| Low temperature characteristics (capacitance rate
of change) |
C25℃-C-55℃/C25℃≤25% |
(25℃,120Hz) |
|||
|
Durability (High Temperature Test) |
The rated voltage is applied at 105°C for 2000h, and after recovery for 24h, the
electrical performance is tested at room temperature (25°C±5°C).: |
||||
| Rate of change in capacitance | ≤±10%Initial measurements | ||||
| DC leakage current | ≤Initial prescriptive value | ||||
| The loss angle is tangent | ≤Initial measurements | ||||
| Esr | ≤200%Initial measurements | ||||
|
Store at high temperatures |
It was stored at 105 °C for 1000h, recovered for 24 h, and tested at room temperature
(25 °C±5 °C).: |
||||
| Rate of change in capacitance | ≤±10%Initial measurements | ||||
| DC leakage current | ≤Initial prescriptive value | ||||
| The loss angle is tangent | ≤Initial measurements | ||||
| Esr | ≤200%Initial measurements | ||||