Index spoľahlivosti radiálneho elektrolytického kondenzátora CABBC pre armádu & obhajoba
- Existujú ukazovatele spoľahlivosti, a päťstupňovú poruchovosť (λ≤1×10-5).
- Veľmi nízky zvodový prúd, ultranízka impedancia, ultra-long life
- Spĺňa environmentálne požiadavky na vibrácie, nízky tlak, humidity resistance and other environmental requirements of the national military standard GJB603-88
- Je vhodný na filtrovanie, väzba a premostenie v elektronických obvodoch v letectve, letectva, alpský, high altitude and ocean
Empty tab. Ak chcete pridať obsah sem, upravte stránku.
Funkcie
◆ 105 ° C, 1000 Zaistené hodiny.
◆ Štandardná miniatúrna veľkosť s výškou 5 mm.
◆ Dodržiavanie predpisov ROHS

| item | characteristic | |||||||
| Operating temperature range | -55℃~+105℃ | |||||||
| Rated voltage range | 10V~100V | |||||||
| Nominal capacitance range | 22μF~1000μF | |||||||
| Allowable deviation of nominal
capacitance (25° C, 120Hz) |
T(-10%~+50%) | |||||||
| DC leakage current(25℃,5min) | I≤0.006CRUR or 1 (čo je väčšie)
CR: Nominálna kapacita (F); Ur: Menovité napätie (Vložka) |
|||||||
|
The loss angle tangent tgδ(25℃,120Hz) |
||||||||
| Ur(Vložka) | 10~25 | 32~63 | 100 | |||||
| tgδ(≤) | 0.13 | 0.08 | 0.07 | |||||
| Temperature characteristics (impedance ratio, 120Hz) | ||||||||
| Ur(Vložka) | 10~25 | 32~50 | 63~100 | |||||
| Z-55°C /Z+25°C | 15 | 10 | 21 | |||||
|
durability |
The rated voltage is applied at 105°C for 2000h, and after recovery for 24h,
the electrical performance of the rated voltage (25°C±5°C) is tested at room temperature |
|||||||
| Rate of change in capacitance | ≤± 20% of the initial measurement | |||||||
| The loss angle tangent tgδ | ≤ 150% of the initial specified value | |||||||
| DC leakage current | ≤ initial prescriptive value | |||||||
|
Store at high temperatures |
After storing at 105 °C for 500 hours and recovering for 24 hodiny, the
electrical properties of the two temperatures (25 °C±5 °C) were tested, and the electrical properties conformed to: |
|||||||
| Rate of change in capacitance | ≤± 10% of the initial measurement | |||||||
| The loss angle tangent tgδ | ≤ 115% of the initial specified value | |||||||
| DC leakage current | ≤ 200% of the initial specified value | |||||||