Radial polymer electrolytic capacitor low ESR CABAD for military & defense
- 125°C series, high heat resistance, leaded
- Low ESR, high frequency and low
- The national military standard level meets the environmental requirements of vibration and low
- It is suitable for energy storage, filtering and bypass in electronic circuits in aerospace, aviation, cold, high altitude and ocean.
Empty tab. Edit page to add content here.
FEATURES
◆ 105°C, 1000 hours assured.
◆ Standard micro miniature size with 5mm height.
◆ RoHS Compliance

| Item | characteristic | |||
| Operating temperature range | -55℃~+125℃ | |||
| Rated operating voltage range | 10V~100V | |||
| Nominal capacitance range | 8.2μF~22000μF | |||
| Allowable deviation of nominal
capacitance |
M(±20%) (25℃,120Hz) | |||
| DC leakage current*1 | I≤0.01CRUR(μA) (25℃,2min)
CR: Nominal capacitance (μF); UR: Rated voltage (V) |
|||
| Loss tangent tgδ (max) | For details, please refer to the “List of Product Specifications and Technical
Parameters”(25℃,120Hz) |
|||
| ESR (maximum)*2 | For details, please refer to the “List of Product Specifications and Technical
Parameters”(25℃,100KHz) |
|||
| Low temperature characteristics
(capacitance rate of change) |
(C25℃°-C55℃)/C25℃≤35% (25℃,120Hz) | |||
|
Durability (High Temperature Test) |
The rated voltage is applied at 125°C for 2000h, and after recovery for 24h, the test is
at room temperature (25°C±5°C), and its electrical performance conforms to: |
|||
| Rate of change in capacitance | ≤± 15% of initial measurements | |||
| DC leakage current | ≤ initial prescriptive value | |||
| The loss angle is tangent | ≤ initial measurements | |||
| ESR | ≤ 200% of the initial measurement | |||
|
Store at high temperatures |
After storage at 125 °C for 1000h, recovery for 24 h, and test at room temperature
(25 °C±5 °C), its electrical performance conforms to: |
|||
| Rate of change in capacitance | ≤± 15% of initial measurements | |||
| DC leakage current | ≤ initial prescriptive value | |||
| The loss angle is tangent | ≤ initial measurements | |||
| ESR | ≤ 200% of the initial measurement | |||